Fuses - Micro Fuses
|
|
FMR
Fuses - Micro Fuses |
|
|
Fast Acting
Radial Lead Micro Fuse
Long Leaded - Cylindrical
|
Electrical Specifications
50mA-6.3A
|
Time Characteristics
|
150% |
1h |
min hold time |
210% |
30s |
max hold
time |
275% |
10ms 3s |
min hold time max hold
time |
400% |
3ms 300ms |
min hold time max hold
time |
1,000% |
20ms |
max hold
time |
Agency
Standards & Listings
|
|
UL Recognized |
50mA-6.3A |
|
CSA Acceptance |
40mA-6.3A |
VDE |
50mA-5A |
MITI |
1A-6.3A |
FMS
Fuses - Micro Fuses |
|
|
Fast Acting
Radial Lead Micro Fuse
Short Leaded - Cylindrical
|
Electrical Specifications
50mA-6.3A
|
Time Characteristics
|
150% |
1h |
min hold time |
210% |
30s |
max hold
time |
275% |
10ms 3s |
min hold time max hold
time |
400% |
3ms 300ms |
min hold time max hold
time |
1,000% |
20ms |
max hold
time |
Agency
Standards & Listings
|
|
UL Recognized |
50mA-6.3A |
|
CSA Acceptance |
40mA-6.3A |
VDE |
50mA-5A |
MITI |
1A-6.3A |
See BMS-01 for Fuse
Holder Information
TMR
Fuses - Micro Fuses |
|
|
Time Lag Radial Lead Micro Fuse
Long Leaded - Cylindrical
|
Electrical Specifications
40mA-6.3A
|
Time Characteristics
|
150% |
1h |
min hold time 40mA-5A, 6.3A |
210% |
2m |
max hold
time 40mA-5A, 6.3A |
275% |
400ms 10s |
min hold time
40mA-5A, 6.3A max hold
time 40mA-5A, 6.3A |
400% |
150ms 3s |
min hold time
40mA-5A, 6.3A max hold
time 40mA-5A, 6.3A |
1,000% |
20ms
15ms
150ms
150ms |
min hold time
40mA-5A
min hold
time 6.3A
max hold time 40mA-5A
max hold time 6.3A
|
Agency
Standards & Listings
|
|
UL Recognized |
40mA-6.3A |
|
CSA Acceptance |
40mA-6.3A |
VDE |
40mA-4A |
MITI |
1A-6.3A |
TMS
Fuses - Micro Fuses |
|
|
Time Lag Radial Lead Micro Fuse
Short Leaded - Cylindrical
|
Electrical Specifications
40mA-6.3A
|
Time Characteristics
|
150% |
1h |
min hold time 40mA-5A, 6.3A |
210% |
2m |
max hold
time 40mA-5A, 6.3A |
275% |
400ms 10s |
min hold time
40mA-5A, 6.3A max hold
time 40mA-5A, 6.3A |
400% |
150ms 3s |
min hold time
40mA-5A, 6.3A max hold
time 40mA-5A, 6.3A |
1,000% |
20ms
15ms
150ms
150ms |
min hold time
40mA-5A
min hold
time 6.3A
max hold time 40mA-5A
max hold time 6.3A
|
Agency
Standards & Listings
|
|
UL Recognized |
40mA-6.3A |
|
CSA Acceptance |
40mA-6.3A |
VDE |
40mA-4A |
MITI |
1A-6.3A |
See BMS-01 for Fuse
Holder Information
FMR-R
Fuses - Micro Fuses
|
|
|
Fast Acting
Radial Lead Micro Fuse
Long Leaded - Rectangular
|
Electrical Specifications
50mA-6.3A
|
Time Characteristics
|
150% |
1h |
min hold time |
210% |
30s |
max hold
time |
275% |
10ms 3s |
min hold time max hold
time |
400% |
3ms 300ms |
min hold time max hold
time |
1,000% |
20ms |
max hold
time |
Agency
Standards & Listings
|
|
UL Recognized |
50mA-6.3A |
|
CSA Acceptance |
40mA-6.3A |
VDE |
50mA-5A |
MITI |
1A-6.3A |
FMS-R
Fuses - Micro Fuses
|
|
|
Fast Acting
Radial Lead Micro Fuse
Short Leaded - Rectangular
|
Electrical Specifications
50mA-6.3A
|
Time Characteristics
|
150% |
1h |
min hold time |
210% |
30s |
max hold
time |
275% |
10ms 3s |
min hold time max hold
time |
400% |
3ms 300ms |
min hold time max hold
time |
1,000% |
20ms |
max hold
time |
Agency
Standards & Listings
|
|
UL Recognized |
50mA-6.3A |
|
CSA Acceptance |
40mA-6.3A |
VDE |
50mA-5A |
MITI |
1A-6.3A |
TMR-R
Fuses - Micro Fuses |
|
|
Time Lag Radial Lead Micro Fuse
Long Leaded - Rectangular
|
Electrical Specifications
40mA-6.3A
|
Time Characteristics
|
150% |
1h |
min hold time 40mA-5A, 6.3A |
210% |
2m |
max hold
time 40mA-5A, 6.3A |
275% |
400ms 10s |
min hold time
40mA-5A, 6.3A max hold
time 40mA-5A, 6.3A |
400% |
150ms 3s |
min hold time
40mA-5A, 6.3A max hold
time 40mA-5A, 6.3A |
1,000% |
20ms
15ms
150ms
150ms |
min hold time
40mA-5A
min hold
time 6.3A
max hold time 40mA-5A
max hold time 6.3A
|
Agency
Standards & Listings
|
|
UL Recognized |
40mA-6.3A |
|
CSA Acceptance |
40mA-6.3A |
VDE |
40mA-4A |
MITI |
1A-6.3A |
TMS-R
Fuses - Micro Fuses |
|
|
Time Lag Radial Lead Micro Fuse
Short Leaded - Rectangular
|
Electrical Specifications
40mA-6.3A
|
Time Characteristics
|
150% |
1h |
min hold time 40mA-5A, 6.3A |
210% |
2m |
max hold
time 40mA-5A, 6.3A |
275% |
400ms 10s |
min hold time
40mA-5A, 6.3A max hold
time 40mA-5A, 6.3A |
400% |
150ms 3s |
min hold time
40mA-5A, 6.3A max hold
time 40mA-5A, 6.3A |
1,000% |
20ms
15ms
150ms
150ms |
min hold time
40mA-5A
min hold
time 6.3A
max hold time 40mA-5A
max hold time 6.3A
|
Agency
Standards & Listings
|
|
UL Recognized |
40mA-6.3A |
|
CSA Acceptance |
40mA-6.3A |
VDE |
40mA-4A |
MITI |
1A-6.3A |
|